The basic version of XIOS UC consists of the Main board (MC), extendable by up to 5 extension modules (MA) and an Expander Board MD1 or MD2.

I/O capacity of the Main Board:

Analogue/digital input Digital output Hall pick-up Sensor supply
11x 2x, max. 4A 2x 2x (5 or 12 VDC configurable)

The XIOS Expander boards MD1 or MD2 offer options for connecting further Extension Boards (MA).

I/O capacity of the Expander Board MD1:

Analogue/digital input Digital input Digital output Inductive pick-up Sensor supply Additional slots
8x 2x 2x, max. 4A 2x 1x (5 or 12 VDC configurable) 6x board MA

Board MD2 is required for the XIOSGenSet and XIOSCHP applications.

I/O capacity of the Expander Board MD2: all possibilities of MD1 and in addition

Digital Input Analogue input AVR output Relay output Addtional slots
4x, isolated 6x AC voltage (3x bus und 3x generator)
4x AC phase current, max. 5 A
1x 1x 3x board MA

  Each of the Extension Modules provides 2 (if isolated), 4 or 8 (if input-only) I/O channels, resulting in a great variety of
  configuration options:

Module type Function
 A2 4x analogue or digital output, monitored, 0...5 VDC (11 mA), 0...24 mA
digital output, max. 1 A PWM controlled (0...100 %)
 A3 4x analogue or digital input, 0...5/10/36 VDC, 0...24 mA
temperature input Pt 1000, Pt 200, Pt 100, Ni 1000, NTC
2x sensor supply (5/12 VDC configurable, 50 mA or VBAT)
 A4 2x analogue or digital input, electrically isolated, 0...5/10/36 VDC, 0...24 mA
temperature input Pt 1000, Pt 200, Pt 100, Ni 1000, NTC
2x sensor supply (5 VDC, 50 mA)
 A5 2x analogue or digital output, electrically isolated, 0...5 VDC (2.5 mA), 0...24 mA
digital output: 60 VDC/40 VAC, 400 mA static, optional: 400 VDC/280 VAC, 100 mA
 A6 2x analogue or digital output, electrically isolated, monitored, 0...5 VDC (10 mA), 0...24 mA
 A7 6x digital input, 9...36 VDC
 A8 up to 4x digital output, high or low-side, current read back for control-loop applications, thermal shutdown
 
 A1 2x thermocouple amplifier, electrically isolated, (J/K/E/R/S/B/N), configurable gain and offset
 A9 1x H bridge output, up to 8 A static current, current read back for control-loop applications

All solutions for your diesel engine

  • EFI Control

    EFI Control

    HEINZMANN masters all electronic injection technologies: complete common rail systems, E-PPN systems, solenoid valve control units and all associated system components through to engine monitoring systems.
  • EFI Control Unit

    EFI Control Unit

    The universal DARDANOS EFI controls combine their main function, speed control, with other performance features that are beneficial to the engine, including optimised fuel efficiency, higher engine output and reduced emissions.
  • High Pressure Pump

    High Pressure Pump

    The high-pressure pumps in the ODYSSEUS HDP-K series are characterised by maximum efficiency and robustness and optimally meet the requirements of harsh industrial environments, guaranteeing efficient and low-maintenance operation.
  • Injectors

    Injectors

    The new generation of ICR-DS injectors has a zero-leakage design that reduces the backflow of fuel by at least 75 % compared to conventional injectors.
  • Pressure Accumulator

    Pressure Accumulator

    The selection of high-pressure accumulator and line systems offered by HEINZMANN can be customised to meet special application and engine-specific requirements.
  • Pressure Limiting Valve

    Pressure Limiting Valve

    Pressure relief valves to protect common rail systems from overpressure. Fast switching for rapid pressure drop.
  • Wastegate Valves

    Wastegate Valves

    Wastegate throttle valves are used to control turbo engines. The throttle valve determines the amount of exhaust gas that drives the turbocharger turbine. HEINZMANN valves exhibit the best sliding properties over a wide temperature range.

We use cookies on our website. However, non-essential cookies (e.g. tracking cookies) are only set if you consent to their use. We point out that in connection with these cookies, your personal data may be transferred to US service providers and merged with other personal data. In the case of data transfers to the USA, there is a risk that this data will be accessed by US authorities without notification and without any legal remedy. With your consent, you also agree to this data transfers to the USA. For more information on the cookies we use, their purposes and storage periods, please refer to our privacy notice at: www.heinzmann.com/en/privacy-policy.